SPECIALIST MEDIUM-VOLTAGE ENGINEERING
Advanced MV Cable Diagnostics, Fault Location & Repair
Independent specialist engineering services for utilities, industry, oil & gas, renewable energy, BESS, airports and critical electrical infrastructure.
From Diagnosis to Verified Cable Integrity
Medium-voltage cable failures can cause significant operational disruption, safety risks and financial losses. Understanding the electrical condition of cable infrastructure is essential for reliable operation and effective asset management.
AGL Engineering S.A. provides independent specialist services covering cable condition assessment, advanced fault localisation, corrective repair engineering and post-repair verification.
Our engineering approach combines specialised high-voltage diagnostic technology, practical field expertise and measured electrical evidence to support reliable operation, targeted intervention and technically justified maintenance or replacement decisions.
From initial investigation to lifecycle recommendations.
Our Engineering Approach
Combining BAUR advanced cable diagnostic technology with Megger high-voltage fault-location systems and complementary specialist instruments.
Our Core Services
✓ MV Cable Condition & Lifecycle Diagnostics
✓ Advanced Fault Location & Pinpointing
✓ Corrective Repair & Recommissioning
✓ Acceptance & Commissioning Verification
Engineering decisions based on measured evidence.
ADVANCED CABLE DIAGNOSTICS
MV Cable Condition Assessment & Lifecycle Diagnostics
Understanding cable condition before deterioration becomes an unexpected failure.
Conventional insulation-resistance and withstand tests provide important electrical information, but do not alone establish the complete condition of an ageing medium-voltage cable system.
AGL Engineering combines advanced high-voltage testing, Tan Delta and Partial Discharge diagnostics with specialist engineering interpretation to identify insulation deterioration, investigate critical weaknesses and support condition-based asset management.
VLF Cable Testing
Controlled Very Low Frequency testing for dielectric withstand verification, commissioning and post-repair assessment of medium-voltage cable systems.
Verified dielectric withstand performance.
Tan Delta (TD) Diagnostics
Dissipation-factor measurements to evaluate overall dielectric insulation condition, identify indications of ageing and support condition trending where reference measurements are available.
Evidence-based insulation condition assessment.
Partial Discharge (PD) Diagnostics
Detection, measurement and localisation of partial discharge activity associated with insulation defects, cable joints, terminations and other electrical weaknesses.
Identification and localisation of critical defects.
Monitored Withstand Testing
Combined high-voltage withstand testing and diagnostic monitoring to evaluate cable behaviour under controlled electrical stress, where technically justified.
Integrated withstand and diagnostic evaluation.
Advanced Diagnostic Technology
Our diagnostic approach is supported by the BAUR PHG 80 VLF test system, PD-TaD 80 diagnostic technology and BAUR Software 4, enabling advanced cable testing, dissipation-factor measurement, partial discharge analysis and structured reporting.
Test methods and voltage levels are selected according to cable voltage class, construction, capacitance, operating condition, applicable standards and the engineering objectives of the assignment.
From Diagnostics to Engineering Decisions
AGL Engineering transforms electrical measurements into documented cable condition assessments, technical risk classifications and prioritised maintenance, repair or replacement recommendations.
Engineering decisions based on measured evidence.
SPECIALIST MV FAULT RESPONSE
Advanced MV Cable Fault Location, Repair & Recommissioning
From accurate fault localisation to verified restoration of cable integrity.
Medium-voltage cable failures require accurate investigation, efficient fault localisation and technically correct corrective intervention. Unnecessary excavation, incomplete fault clearance and inadequate repair verification can lead to repeated failures and extended operational downtime.
AGL Engineering combines advanced Megger fault-location technology, specialised diagnostic instruments and practical cable repair expertise to support the complete fault-response process, from initial investigation through repair to documented recommissioning.
Fault Characterisation & Pre-location
Systematic investigation of conductor, insulation and high-resistance cable faults using the Megger STX40 high-voltage fault-location platform.
Integrated TDR, ARM, ICE and DECAY methods support accurate fault-distance estimation and selection of the appropriate subsequent investigation.
Accurate fault characterisation and targeted pre-location.
Precise Pinpointing & Cable Identification
Accurate field pinpointing using acoustic-electromagnetic detection, cable route tracing and specialist cable identification methods to establish the fault position before excavation.
BAUR shirla and Megger HVB10 provide complementary capabilities for cable sheath testing, resistance-based fault pre-location and sheath fault investigation.
Targeted excavation and positive cable identification.
Corrective MV Cable Repair
Targeted removal of defective cable sections, replacement cable installation, straight-through or transition jointing and termination repair according to the cable construction and confirmed accessory requirements.
Particular attention is given to conductor connections, metallic screen continuity, bonding, insulation integrity and watertight oversheath restoration.
Technically controlled repair and restoration of cable integrity.
Post-Repair Verification & Recommissioning
Electrical verification of repaired cable sections using insulation-resistance measurements, oversheath integrity testing and appropriate VLF withstand procedures where technically justified.
Documented verification results, repair records and updated cable information support technically justified recommissioning and future maintenance.
Verified repair condition and documented return-to-service support.
Advanced Fault-Location Technology
Our principal fault-location capability is based on the Megger STX40 high-voltage cable fault-location system, supported by dedicated reflectometry, surge pinpointing, cable tracing and identification equipment.
Complementary BAUR shirla, Megger HVB10 and high-range insulation diagnostic instruments enable investigations of cable sheath defects, resistance-based faults and complex electrical failure conditions.
Fault-location and corrective methods, including controlled fault conditioning where necessary, are selected according to the cable system, fault characteristics, operating environment and applicable safety requirements.
From Fault Investigation to Verified Restoration
AGL Engineering provides documented fault-location findings, corrective repair records, post-repair electrical verification and technical recommendations to support reliable return to service.
Locate accurately. Repair correctly. Verify electrically.
SPECIALIST HIGH-VOLTAGE TECHNOLOGY
Advanced Diagnostic & Fault-Location Equipment
Advanced high-voltage test and fault-location technology supporting accurate measurements, technically justified interventions and reliable engineering decisions.
AGL Engineering's specialist MV cable engineering capability is built around two principal technology platforms: BAUR high-voltage cable diagnostics and Megger advanced cable fault-location systems.
Complementary instrumentation supports sheath integrity testing, insulation diagnostics, fault pinpointing, cable identification and electrical connection verification.
BAUR PHG 80 / PD-TaD 80
Advanced Cable Testing & Condition Diagnostics
Advanced VLF cable testing combined with Tan Delta and Partial Discharge diagnostics for electrical condition assessment, commissioning verification and lifecycle planning.
Technical Capabilities
VLF pure sinusoidal: up to 57 kV RMS
Tan Delta diagnostics: up to 57 kV RMS
Partial Discharge: coupling system rated up to 80 kV peak (57 kV RMS)
VLF square-wave: up to 80 kV
DC output: up to ±80 kV
Diagnostic functions: TD, PD, TD/PD and Monitored Withstand Testing
Cable condition evaluation, defect identification and evidence-based lifecycle recommendations.
Megger STX40
Advanced Cable Fault Location & Conversion
Integrated high-voltage cable fault-location technology for systematic fault characterisation, accurate pre-location, surge pinpointing and controlled fault conversion.
Technical Capabilities
TDR: integrated cable reflectometry
ARM: up to 32 kV
ICE: up to 32 kV
DECAY: up to 40 kV
Surge pinpointing: up to 32 kV / 2,000 J
DC testing: up to 40 kV
Fault burning: up to 40 kV DC
Accurate fault localisation, reduced unnecessary excavation and controlled corrective intervention.
Complementary Specialist Instrumentation
BAUR shirla
Cable sheath integrity testing, sheath fault pre-location and pinpointing.
Megger HVB10
High-voltage bridge measurements and resistance-based cable and sheath fault localisation.
Megger S1-1568/2
High-range insulation-resistance and Polarization Index diagnostics.
Additional Specialist Equipment
TDR, acoustic-electromagnetic pinpointing, cable route tracing, cable identification and Kelvin micro-ohm measurements.
Specialist Technology. Engineering Expertise. Verified Results.
Equipment selection, test voltage and diagnostic methodology are determined by the cable system, its operating condition, applicable standards and the engineering objectives of each assignment.
Engineering decisions based on measured evidence.
Stated maximum values are equipment ratings, not prescribed test voltages. Actual test capability depends on system configuration, cable capacitance and the selected test method.
DOCUMENTED ENGINEERING OUTCOMES
From Measurements to Engineering Decisions
Technical evidence that supports safe operation, effective maintenance and informed investment decisions.
Electrical measurements provide essential information, but their real value lies in technically justified engineering interpretation.
AGL Engineering translates diagnostic findings, fault investigations and post-repair verification results into structured technical reports and practical recommendations. This enables infrastructure owners and operators to understand cable condition, evaluate risks and prioritise corrective actions and future investments.
DELIVERABLE 01
Cable Condition Assessment
Documented diagnostic findings, insulation condition evaluation, identification of significant electrical weaknesses and circuit-level technical risk classification.
Understand the condition of your MV cable assets.
DELIVERABLE 02
Fault Investigation & Repair Records
Fault characterisation and localisation findings, identified defects, corrective repair documentation and records of replaced cable sections or accessories.
Document the fault and the corrective intervention.
DELIVERABLE 03
Verification & Recommissioning
Post-repair electrical test results, verification of applicable acceptance criteria, recorded observations and technical evidence supporting recommissioning decisions.
Establish documented post-intervention electrical condition.
DELIVERABLE 04
Lifecycle & Investment Recommendations
Prioritised engineering recommendations for maintenance, further investigation, rehabilitation or cable replacement, based on measured condition and identified technical risks.
Support condition-based maintenance and investment planning.
Supporting MV Infrastructure Across Industries
Our specialist engineering services support power utilities, industrial plants, oil and gas installations, renewable energy facilities, BESS projects, airports, ports and other critical electrical infrastructure.
Assignments range from investigating an individual defective cable feeder to comprehensive condition assessments of complete MV cable networks, with the scope tailored to the installation and operational requirements.
Your MV Infrastructure Deserves Verified Engineering Evidence
Whether you require advanced cable diagnostics, urgent fault investigation, corrective repair or long-term asset condition assessment, AGL Engineering can provide independent specialist engineering support.
Engineering decisions based on measured evidence.
Diagnostic methods, reporting scope and recommendations are tailored to the cable system, technical condition, applicable standards and agreed assignment objectives.